Passive Pre-Cooling Potential For Reducing Building Air-Conditioning Loads in Hot Climates PDF

Passive Pre-Cooling Potential For Reducing Building Air-Conditioning Loads in Hot Climates PDF

Name:
Passive Pre-Cooling Potential For Reducing Building Air-Conditioning Loads in Hot Climates PDF

Published Date:
2014

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
passive-pre-cooling-potential-for-reducing-building-air-conditioning-loads-in-hot-climates_1876429

Choose Document Language:
4.80
Need Help?

A major source of energy consumption in the building sector is the extensive use of Heating, Ventilation and Air-Conditioning (HVAC) systems to meet the rising demands for indoor comfort. Advancements in reducing cooling loads will have a direct impact on energy consumption in the built environment. The present study investigated the thermal performance of a heat pipe heat exchanger in transferring sensible heat from high temperature natural air streams. In order to ensure the system's sustainable operation, water was used as the working fluid and heat is transferred using its indirect evaporation phenomenon. The physical domain comprised of 19 cylindrical copper heat pipes measuring 800 mm in length and 15.9 mm in internal diameter, assembled in a systematic arrangement at an angle of 90° with respect to ground. The heat pipes were divided by a separator plate to segregate the evaporator and condenser ends from each other. Hot air at 41°C was delivered to the evaporator end while a temperature of 15°C was maintained in control volume at the condenser end. Computational Fluid Dynamics (CFD) was used in order to analyze the heat pipe model at fixed inlet velocities of 1m/s and 2.3m/s. The results showed a maximum temperature reduction of 3.8°C at an external air velocity of 1m/s, delivering an internal air temperature of 37.2°C. A cooling load of 976W was achieved indicating a heat pipe effectiveness of 6.4% when the velocity was increased to 2.3m/s. The numerical values predicted at the measurement locations were compared against experimental results for the purpose of validation. Good correlation was observed between the two techniques with error variations of 10% for air velocity and 28% for air temperature. The present study identified the potential of sustainable pre-cooling using a heat pipe heat exchanger in natural ventilation air streams for regions incorporating hot and dry climatic conditions.


File Size : 1 file , 2.4 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-2014FICEConf-2-2
Published : 2014

History


Related products


Best-Selling Products

ISO/PAS 11585:2023
Published Date: 09/01/2023
Road vehicles - Partial driving automation - Technical characteristics of conditional hands-free driving systems
37.20 €
ISO/PAS 11819-4:2013
Published Date: 03/15/2013
Acoustics - Method for measuring the influence of road surfaces on traffic noise - Part 4: SPB method using backing board
20.40 €
ISO/PAS 11856:2003
Published Date: 01/01/2003
Textile floor coverings - Test methods for the determination of fibre bind
34.20 €
ISO/PAS 12006-3:2001
Published Date: 10/01/2001
Building construction - Organization of information about construction works - Part 3: Framework for object-oriented information exchange
27.60 €
ISO/PAS 12158:2002
Published Date: 07/01/2002
Road vehicles - Braking systems - Temperature measuring methods
20.40 €
ISO/PAS 12835:2013
Published Date: 12/15/2013
Qualification of casing connections for thermal wells
75.00 €