SA-12-002 -- Using Energy Flow Analysis to Assess Energy Savings from Recirculation Controls in Multi-Family Central Domestic Hot Water Systems PDF

SA-12-002 -- Using Energy Flow Analysis to Assess Energy Savings from Recirculation Controls in Multi-Family Central Domestic Hot Water Systems PDF

Name:
SA-12-002 -- Using Energy Flow Analysis to Assess Energy Savings from Recirculation Controls in Multi-Family Central Domestic Hot Water Systems PDF

Published Date:
2012

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?
Recirculation loops (RL) in multi-family central domestic hot water (DHW) systems bring hot water close to dwelling units to provide tenants with quick access to hot water. However, long RL pipes make them a major source of system heat loss. Previous studies assessed energy savings by different RL control technologies based on measurement of overall system energy consumptions, and they did not reach definite conclusions. Overall energy consumption is affected by many operational parameters. Without evaluating RL pipe heat loss directly, energy savings cannot be accurately assessed and energy savings mechanisms cannot be well understood. This paper presents an energy flow analysis method to assess RL pipe heat loss based on field measurements of pipe temperatures and water flows. This method further separates the RL pipe heat loss into two components, one associated with the recirculation flow heat loss and one associated with hot water draw flow heat loss, so that the direct impact of controls to RL pipe heat loss was revealed. The energy flow analysis method also provided a way to characterize central DHW system performance by based on percentage weighting of four major energy flow components, including water heater loss, RL pipe heat loss, branch pipe heat loss and hot water draw energy, in the overall system energy consumption. Our field study results indicated that RL pipe heat loss represented about one third of system fuel energy consumption and the average overall system efficiency was only about 34%.
File Size : 1 file , 2.9 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 10
Product Code(s) : D-SA-12-002
Published : 2012

History


Related products


Best-Selling Products

CGSB 1-GP-151M
Published Date: 03/01/1980
Standard for Coating, Interior, Intumescent, Fire Retardant
Free Download
CGSB 1-GP-151M
Published Date: 03/01/1980
Revetement de peinture, interieur, intumescent, ignifuge
Free Download
CGSB 1-GP-180MA
Published Date: 02/01/1996
Coating, Polyurethane, Two-Package, General Purpose
Free Download
CGSB 1-GP-180MA
Published Date: 02/01/1996
Revetement de polyurethanne, a deux constituants separes, pour utilisation generale
Free Download
CGSB 1-GP-191M AMEND.
Published Date: 03/01/1981
Enamel, Automotive Refinishing, Fast Drying, Gloss
CGSB 1-GP-191M AMEND.
Published Date: 03/01/1981
Peinture-email brillante, a sechage rapide, pour le repeinturage des carrosseries de vehicules automobiles