TA-23-C016 – Cooling Energy Savings in Data Centers in Hot and Humid Climates Using a Dehumidification-Assisted Evaporated Cooling System PDF

TA-23-C016 – Cooling Energy Savings in Data Centers in Hot and Humid Climates Using a Dehumidification-Assisted Evaporated Cooling System PDF

Name:
TA-23-C016 – Cooling Energy Savings in Data Centers in Hot and Humid Climates Using a Dehumidification-Assisted Evaporated Cooling System PDF

Published Date:
2023

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Data centers are essential infrastructures for various IT services. As the number of IT servers increases, global data centers consume 1,002 billion kWh of electricity annually. The cooling systems of data centers accounts for approximately 30–40% of the power consumption. Free cooling systems have been increasingly used to reduce the power consumption of data centers, and various such systems have been proposed to further improve efficiency. However, the performance of the cooling towers of the free cooling systems are limited during summer caused by to hot and humid environments. This limitation minimizes the temperature drop of the coolant, even if it exhibits effective cooling effects during winter. To overcome this limitation, this study proposed a liquid desiccant cooling system that improves the performance of the cooling tower by lowering the wet bulb temperature of ambient air and reduces the energy consumption of the chiller. The proposed liquid desiccant cooling system is a method that lowers the wet bulb temperature of outdoor air using the difference in the partial pressures of water vapor as high-temperature and humid outdoor air passes through an absorber during summer. Additionally, the heat of condensation generated in the condenser is recovered and used as a heating source for regenerating an aqueous solution to achieve more energy savings. This method eliminates additional regenerative heat sources. An experiment was conducted using EES simulation to investigate the effects of the proposed LD cooling system under various environmental conditions, including the subtropical climate of America, the temperate climate of the Republic of Korea, and the tropical climate of Vietnam. The proposed LD cooling system successfully lowered the wet bulb temperature of the outdoor air and improved the performance of the cooling tower. The results show that the proposed LD cooling system reduced the energy consumption by 35.68% under the temperate climatic conditions, 26.59% under the subtropical climatic conditions, and 26.31% under the tropical climatic conditions. This confirms that the proposed LD cooling system is beneficial for data centers built in subtropical, temperate, and tropical climates.


File Size : 1 file , 2 MB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-TA-23-C016
Published : 2023

History


Related products


Best-Selling Products

NFSI B101.0-2017
Published Date: 01/11/2017
Walkway Surface Auditing Procedure for the Measurement of Walkway Slip Resistance
$19.5
NFSI B101.0-2021
Published Date: 03/12/2021
Walkway Surface Auditing Procedure for the Measurement of Walkway Slip Resistance
$19.5
NFSI B101.1-2009
Published Date: 10/13/2009
Test Method for Measuring Wet SCOF of Common Hard-Surface Floor Materials
$18
NFSI B101.1-2020
Published Date: 2020
Test Method for Measuring Wet SCOF of Common Hard-Surface Floor Materials
$18
NFSI B101.2-2020
Published Date: 2020
Test Method for Determining the Impact on Wet Coefficients of Friction of Various Chemical or Physical Walkway Surface Cleaners and Treatments on Common Hard-Surface Flooring Materials
$18
NFSI B101.3-2012
Published Date: 01/18/2012
Test Method for Measuring Wet DCOF of Common Hard-Surface Floor Materials
$18