The Impact of Part-Load Air-Conditioner Operation on Dehumidification Performance: Validating a Latent Capacity Degradation Model PDF

The Impact of Part-Load Air-Conditioner Operation on Dehumidification Performance: Validating a Latent Capacity Degradation Model PDF

Name:
The Impact of Part-Load Air-Conditioner Operation on Dehumidification Performance: Validating a Latent Capacity Degradation Model PDF

Published Date:
1998

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Constant-volume air-conditioning systems provide space conditioning in many residential and commercial buildings. In these applications, the compressor typically cycles on and off to meet the cooling load, while the supply fan operates constantly to ensure the zone is well mixed. Under this scenario, it has been demonstrated that the dehumidification capacity of an air-conditioning system degrades at part-load conditions because moisture on the cooling coil surface evaporates back into the airstream when cooling is deactivated. Henderson and Rengarajan (1996) developed an engineering model of this phenomenon suitable for use in hourly building simulations as well as other types of analysis. The model considers conditions entering the coil, thermostat cycling rates, air-conditioner transient performance, and the moisture- retaining characteristics of the cooling coil.

Previous laboratory measurements have shown that during the OFF cycle, the cooling coil essentially acts as an evaporative cooler, adiabatically providing both sensible cooling and moisture addition. This paper uses that knowledge to determine the moisture evaporation characteristics of a cooling coil installed in a residence with relatively simple temperature measurements. Field-monitored data for a residential water-to-air heat pump are used to determine required parameters for the latent degradation model. The model was able to properly predict the measured latent degradation effects measured over the cooling season. The paper also discusses the other types of experimental data that would be required to further validate the model for various classes of cooling coils and operating scenarios.


Authors: Hugh I. Henderson, Jr., P.E.
Citation: IAQ and Energy 98 Using ASHRAE Standards 62 and 90.1 Conference Papers
Keywords: October, Louisiana, 1998


File Size : 1 file , 270 KB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-8125
Published : 1998

History


Related products


Best-Selling Products

NRCA 0427
Published Date: 01/01/2013
The NRCA Roofing Manual: Steep-slope Roof Systems
$96.6
NRCA 0434
Published Date: 01/01/2019
THE NRCA ROOFING MANUAL: MEMBRANE ROOF SYSTEMS
$195.6
NRCA 0434
Published Date: 01/01/2015
THE NRCA ROOFING MANUAL: MEMBRANE ROOF SYSTEMS
$96.6
NRCA 0436
Published Date: 01/01/2016
The NRCA Roofing Manual: Metal Panel and SPF Roof Systems
$96.6
NRCA 3760
Published Date: 01/01/2010
Building Owners Guide to Roof-mounted Photovoltaic Systems
$19.8
NRCA 3767
Published Date: 01/01/2012
NRCA Guidelines for Roof Systems With Rooftop Photovoltaic Components