Investigation of a Fin-and-Tube Surface as a Contaminant Sink PDF

Investigation of a Fin-and-Tube Surface as a Contaminant Sink PDF

Name:
Investigation of a Fin-and-Tube Surface as a Contaminant Sink PDF

Published Date:
1998

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The HVAC system can be both a sink and a source of contaminants; however, being a source of contamination is a direct product of being a sink of pollutants. In order to understand the HVAC system as a pollution source, one must first understand the HVAC system as a sink of contaminants. Characteristics of contaminant aerosol deposition on the fin and tube surfaces for typical air-conditioning evaporator coils were examined, and numerical methods were used to provide an understanding of the deposition of aerosols on fin and tube surfaces of an evaporator coil. A combination of two airflow rates (1.5 m/s or 4.9 ft/s and 2.3 m/s or 7.6 ft/s), two coil orientations (horizontal and vertical), three fin spacing (3.9 fins/cm or 10 fins/in., 4.7 fins/cm or 12 fins/in., and 5.5 fins/cm or 14 fins/in.), and particle size (ranging from 1 to 100 µm aerodynamic diameter) were examined. Particle sizes chosen are representative of microbiological and other contaminants that can affect actual and perceived indoor air quality. Results indicate that the evaporator coil will collect significant amounts of aerosol in the particle size range of 5-100 µm AD.

Authors: Arnoldo Muyshondt, Ph.D., P.E., Darin W. Nutter, Ph.D., P.E., Matthew H. Gordon, Ph.D., P.E.
Citation: IAQ and Energy 98: Using ASHRAE Standards 62 and 90.1 Conference Papers
Keywords: October, Louisiana, 1998


File Size : 1 file , 240 KB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-8139
Published : 1998

History


Related products


Best-Selling Products

CPSC 16 CFR PART 1130
Published Date: 01/01/2018
REQUIREMENTS FOR CONSUMER REGISTRATION OF DURABLE INFANT OR TODDLER PRODUCTS
$9.3
CPSC 16 CFR PART 1209
Published Date: 01/01/2018
INTERIM SAFETY STANDARD FOR CELLULOSE INSULATION
$12
CPSC 16 CFR PART 1220
Published Date: 01/01/2019
SAFETY STANDARD FOR NON-FULL-SIZE BABY CRIBS
$8.7
CPSC 16 CFR PART 1250
Published Date: 01/01/2022
SAFETY STANDARD MANDATING ASTM F963 FOR TOYS
$8.4
CPSC 16 CFR PART 1250
Published Date: 01/01/2023
SAFETY STANDARD MANDATING ASTM F963 FOR TOYS
$8.4
CPSC 16 CFR PART 1250
Published Date: 01/01/2024
SAFETY STANDARD MANDATING ASTM F963 FOR TOYS
$8.4