The HVAC system can be both a sink and a source of contaminants; however, being a source of contamination is a direct product of being a sink of pollutants. In order to understand the HVAC system as a pollution source, one must first understand the HVAC system as a sink of contaminants. Characteristics of contaminant aerosol deposition on the fin and tube surfaces for typical air-conditioning evaporator coils were examined, and numerical methods were used to provide an understanding of the deposition of aerosols on fin and tube surfaces of an evaporator coil. A combination of two airflow rates (1.5 m/s or 4.9 ft/s and 2.3 m/s or 7.6 ft/s), two coil orientations (horizontal and vertical), three fin spacing (3.9 fins/cm or 10 fins/in., 4.7 fins/cm or 12 fins/in., and 5.5 fins/cm or 14 fins/in.), and particle size (ranging from 1 to 100 µm aerodynamic diameter) were examined. Particle sizes chosen are representative of microbiological and other contaminants that can affect actual and perceived indoor air quality. Results indicate that the evaporator coil will collect significant amounts of aerosol in the particle size range of 5-100 µm AD.

Authors: Arnoldo Muyshondt, Ph.D., P.E., Darin W. Nutter, Ph.D., P.E., Matthew H. Gordon, Ph.D., P.E.
Citation: IAQ and Energy 98: Using ASHRAE Standards 62 and 90.1 Conference Papers
Keywords: October, Louisiana, 1998


File Size : 1 file , 240 KB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-8139
Published : 1998

History


Related products


Best-Selling Products

BIFMA Color 3.1-2005
Published Date: 2009
Standard for Color Measurement for Office Furniture Manufacturers and Suppliers
BIFMA G1-2002
Published Date: 2002
2001 Ergonomics Guideline
BIFMA G1-2013 Guideline
Published Date: 2013
Ergonomics Guideline: Ultimate Test for Fit
BIFMA G1-2013
Published Date: 2013
2013 Ergonomics Guideline for Furniture used in Office Work Spaces Designed for Computer Use
BIFMA HCF 8.1-2017
Published Date: 2017
Health Care Furniture Design Guidelines For Cleanability
BIFMA HCF 8.1-2019
Published Date: 2019
Health Care Furniture Design Guidelines For Cleanability