TO-22-C014 - Joint Optimization of HVAC and Active Insulation Control Strategies in Residential Buildings PDF

TO-22-C014 - Joint Optimization of HVAC and Active Insulation Control Strategies in Residential Buildings PDF

Name:
TO-22-C014 - Joint Optimization of HVAC and Active Insulation Control Strategies in Residential Buildings PDF

Published Date:
2022

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Increasing building construction thermal resistance has been shown to be an effective traditional way of improving building energy efficiency. In this approach, the opaque building envelope is often deemed to be a static system that keeps the indoor environment isolated from the outdoor environment. More recently, active insulation systems (AIS) have been conceptualized to enable active control over building envelope thermal properties, allowing the thermal resistance to be optimally modulated in response to changing environmental conditions. Dynamically tuning the building thermal performance can lead to increased energy savings, reduced operating costs, and reductions in operational carbon emissions. When paired with thermal mass, AIS can also increase building load flexibility for providing demand response and grid services. Building flexibility can further be improved if the building is also equipped with optimized HVAC system controls. In this configuration, the AIS and HVAC systems can be beneficially coordinated to optimally condition the space based on the desired operational objectives.

In this work, we quantify the potential benefits of jointly optimizing AIS and HVAC system controls by applying model predictive control to a detailed whole-building energy model. The example building is an all-electric single-family residential building, satisfying IECC 2012, in Baltimore, MD. To highlight the increase in benefits from jointly optimizing HVAC and dynamic envelope systems, we compare the results to the performance achieved when optimizing HVAC and AIS systems individually. Results showed that the combined optimization of HVAC and AIS control was able to achieve 13% peak demand reduction, while savings 3% energy. This is in contrast to only a 10% peak reduction and 16% increase in energy use for the case with optimized HVAC only. These results ultimately motivate further exploration, integration, and joint optimization of dynamic envelope and HVAC system components.


File Size : 1 file , 2.5 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-TO-22-C014
Published : 2022
Units of Measure : Dual

History


Related products


Best-Selling Products

ICAO 10000
Published Date: 2014
Manual on Flight Data Analysis Programmes (FDAP)
ICAO 10000
Published Date: 01/01/2014
Manual on Flight Data Analysis Programmes (FDAP)
ICAO 10000
Published Date: 01/01/2021
Manual on Flight Data Analysis Programmes (FDAP)
ICAO 10000
Published Date: 01/01/2021
Руководство по программам анализа полетных данных (ПАПД)
ICAO 10000
Published Date: 01/01/2021
Manuel sur les programmes d’analyse des données de vol (FDAP)
ICAO 10000
Published Date: 01/01/2014
Manual on Flight Data Analysis Programmes (FDAP)