SN-CEN ISO/TS 9241-430:2023 PDF

SN-CEN ISO/TS 9241-430:2023 PDF

Name:
SN-CEN ISO/TS 9241-430:2023 PDF

Published Date:
04/21/2023

Status:
Active

Description:

Ergonomics of human-system interaction — Part 430: Recommendations for the design of non-touch gestural input for the reduction of biomechanical stress (ISO/TS 9241-430:2021)

Publisher:
Standards Norway SN-CEN ISO/TS Series

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
sn-cen-iso-ts-9241-430-2023_2571639

Choose Document Language:
0
Need Help?
ADOPTED_FROM:CEN ISO/TS 9241-430:2023

This document provides guidance on the design, selection and optimization of non-contacting hand and arm gestures for human-computer interaction. It addresses the assessment of usability and fatigue associated with different gesture set designs and provides recommendations for approaches to evaluating the design and selection of gestures. This document also provides guidance on the documentation of the process for selecting gesture sets.
This document applies to gestures expressed by humans. It does not consider the technology for detecting gestures or the system response when interpreting a gesture. Non-contacting hand gestures can be used for input in a variety of settings, including the workplace or in public settings and when using fixed screens, mobile, virtual reality, augmented reality or mixed-mode reality devices.
Some limitations of this document are:
—    The scope is limited to non-contacting gestures and does not include other forms of inputs. For example, combining gesture with speech, gaze or head position can reduce input error, but these combinations are not considered here.
—    The scope is limited to non-contacting arm, hand and finger gestures, either unilateral (one-handed) or bilateral (two-handed).
—    The scope assumes that all technological constraints are surmountable. Therefore, there is no consideration of technological limitations with interpreting ultra-rapid gestures, gestures performed by people of different skin tones or wearing different colours or patterns of clothing.
—    The scope is limited to UI-based command-and-control human computer interaction (HCI) tasks and does not include gaming scenarios, although the traversal of in-game menus and navigation of UI elements is within scope.
—    The scope does not include HCI tasks for which an obviously more optimal input method exists. For example, speech input is superior for inputting text than gesture input.
—    The scope includes virtual reality (VR), augmented reality (AR) and mixed reality (MR) and the use of head-mounted displays (HMDs).
—    The scope does not include the discoverability of gestures but does include the learnability and memorability of gestures. It is assumed that product documentation and tutorials will adequately educate end users about which gestures are possible. Therefore, assessing gesture discoverability is not a primary goal of the recommendations in this document.


Number of Pages : 28
Published : 04/21/2023

History


Related products


Best-Selling Products

AAMI 11135:1994
Published Date: 05/01/1994
Medical Devices - Validation and Routine Control of Ethylene Oxide Sterilization - Includes Errata
29.70 €
AAMI 11607:1997
Published Date: 02/24/1997
Packaging for terminally sterilized medical devices
AAMI 11663:2014
Published Date: 08/08/2014
Quality of dialysis fluid for hemodialysis and related therapies
AAMI 11737-1
Published Date: 09/01/1995
Sterilization of Medical Devices - Microbiological Methods - Part 1: Estimation of the Population of Microorganisms on Product
26.40 €
AAMI 11737-2
Published Date: 09/01/1998
Sterilization of medical devices - Microbiological methods - Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process
26.40 €
AAMI 13958:2014
Published Date: 08/15/2014
Concentrates for hemodialysis and related therapies