Description:

Standard Practice for Evaluating the Performance of Respirable Aerosol Samplers

Publisher:
ASTM International

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$18
Need Help?

1.1 This practice covers the evaluation of the performance of personal samplers of non-fibrous respirable aerosol. The samplers are assessed relative to a specific respirable sampling convention. The convention is one of several that identify specific particle size fractions for assessing health effects of airborne particles. When a health effects assessment has been based on a specific convention it is appropriate to use that same convention for setting permissible exposure limits in the workplace and ambient environment and for monitoring compliance. The conventions, which define inhalable, thoracic, and respirable aerosol sampler ideals, have now been adopted by the International Standards Organization (Technical Report ISO TR 7708), the Comit Europen de Normalisation (CEN Standard EN 481), and the American Conference of Governmental Industrial Hygienists (ACGIH, Ref (1)), developed (2) in part from health-effects studies reviewed in Ref (3) and in part as a compromise between definitions proposed in Refs (3,4).

1.2 This practice is complimentary to Test Method D 4532, which specifies a particular instrument, the 10-mm cyclone. The sampler evaluation procedures presented in this practice have been applied in the testing of the 10-mm cyclone as well as the Higgins-Dewell cyclone.3,4 Details on the evaluation have been recently published (5-7) and can be incorporated into revisions of Test Method D 4532.

1.3 A central aim of this practice is to provide information required for characterizing the uncertainty of concentration estimates from samples taken by candidate samplers. For this purpose, sampling accuracy data from the performance tests given here can be combined with information as to analytical and sampling pump uncertainty obtained externally. The practice applies principles of ISO GUM, expanded to cover situations common in occupational hygiene measurement, where the measurand varies markedly in both time and space. A general approach (8) for dealing with this situation relates to the theory of tolerance intervals and may be summarized as follows: Sampling/analytical methods undergo extensive evaluations and are subsequently applied without re-evaluation at each measurement, while taking precautions (for example, through a quality assurance program) that the method remains stable. Measurement uncertainty is then characterized by specifying the evaluation confidence (for example, 95 %) that confidence intervals determined by measurements bracket measurand values at better than a given rate (for example, 95 %). Moreover, the systematic difference between candidate and idealized aerosol samplers can be expressed as a relative bias, which has proven to be a useful concept and is included in the specification of accuracy (3.2.9-3.2.10).

1.4 Units of the International System of Units (SI) are used throughout this practice and should be regarded as standard.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.


File Size : 1 file , 110 KB
Note : This product is unavailable in Russia, Ukraine, Belarus
Number of Pages : 9
Published : 10/10/2001
Redline File Size : 2 files , 270 KB

History

ASTM D6061-01(2018)e1
Published Date: 12/01/2018
Standard Practice for Evaluating the Performance of Respirable Aerosol Samplers
$14.4
ASTM D6061-01(2012)e1
Published Date: 04/01/2012
Standard Practice for Evaluating the Performance of Respirable Aerosol Samplers
$18
ASTM D6061-01(2007)e1
Published Date: 04/01/2007
Standard Practice for Evaluating the Performance of Respirable Aerosol Samplers
$18
ASTM D6061-01
Published Date: 10/10/2001
Standard Practice for Evaluating the Performance of Respirable Aerosol Samplers
$18
ASTM D6061-96
Published Date: 01/01/1996
Standard Practice for Evaluating the Performance of Respirable Aerosol Samplers
$17.4

Related products

ASTM D5281-98(2013)
Published Date: 11/01/2013
Standard Test Method for Collection and Analysis of Hexavalent Chromium in Ambient Atmospheres (Withdrawn 2014)
$18
ASTM D6420-18
Published Date: 11/01/2018
Standard Test Method for Determination of Gaseous Organic Compounds by Direct Interface Gas Chromatography-Mass Spectrometry
69.00 48.00 you save 21.00
ASTM D4861-23
Published Date: 09/01/2023
Standard Practice for Sampling and Selection of Analytical Techniques for Pesticides and Polychlorinated Biphenyls in Air
$18.9
ASTM E1687-19
Published Date: 10/01/2019
Standard Test Method for Determining Carcinogenic Potential of Virgin Base Oils in Metalworking Fluids
$15

Best-Selling Products

ETSI Draft EN 301 908-13
Published Date: 11/01/2021
IMT cellular networks; Harmonised Standard for access to radio spectrum; Part 13: Evolved Universal Terrestrial Radio Access (E-UTRA) User Equipment (UE)
$9.81
ETSI EG 200 053
Published Date: 06/01/2004
Electromagnetic compatibility and Radio spectrum Matters (ERM); Radio site engineering for radio equipment and systems
$9.81
ETSI EG 200 234
Published Date: 02/01/2000
Telecommunications security; A guide to specifying requirements for cryptographic algorithms
21.80 21.31 you save 0.49
ETSI EG 200 351
Published Date: 09/01/1997
ETSI object identifier tree; Rules and registration procedures
$4.164
ETSI EG 200 351
Published Date: 09/01/1998
ETSI object identifier tree; Rules and registration procedures
$4.164
ETSI EG 200 351
Published Date: 10/01/1999
ETSI object identifier tree; Rules and registration procedures
17.83 17.34 you save 0.49