AWWA ACE95130 PDF

AWWA ACE95130 PDF

Name:
AWWA ACE95130 PDF

Published Date:
01/01/1995

Status:
Active

Description:

Considerations for the Planning and Design of Improvements to an Existing Water Supply Facility

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
Water purveyors face the demanding task of supplying clean water to satisfy the demands of their constituents. Often, existing facilities must be expanded to increase the amount of water available for daily use and for fire protection. Other facilities may require upgrading to meet more stringent water quality regulations. This paper focuses on the planning and design of improvements to a 50-year old water treatment and distribution system located in Beltsville, Maryland. A hydraulic model of the system incorporating CYBERNET software revealed areas needing improvement including: low pressure areas, low flow areas, unaccounted-for water, deteriorated storage facilities, and insufficient finished water storage. The recommended improvements to the distribution system included cleaning and lining of nearly 3,000 feet of existing 8 inch water mains and the installation of over 6 miles of 8 inch to 16 inch ductile iron water distribution mains. Unaccounted-for water was significant for the facility. A leak detection program identified over 53,000 gallons per day of leaks. Recommendations for the storage system proposed the rehabilitation of three elevated water storage tanks and the construction of new 300,000 gallon finished water storage tank. An environmental assessment and an archaeological survey were completed to aid in the rehabilitation. The plant improvements are expected to be completed in 1998.
File Size : 1 file
ISBN(s) : 0898678358
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 9
Published : 01/01/1995

History


Related products

AWWA ACE95165
Published Date: 01/01/1995
Useful or Useless Models: A Procedure for Maintaining Network Models
$7.2
AWWA ACE95157
Published Date: 01/01/1995
Lead Based Paint: Living With the OSHA Standard
$7.2
AWWA ACE95145
Published Date: 01/01/1995
Application of Intelligent Seismic Sensor Technology for Loss-Reduction in the Water and Waste-Water Industries
$7.2
AWWA ACE95139
Published Date: 01/01/1995
Conversion From Gravity to Pressurized Flow: The 60 MGD Puddletown Booster Station
$7.2

Best-Selling Products

FAO/WHO FAO8876
Published Date: 01/01/2003
Food Quality and Safety Systems: A Training Manual on Food Hygiene and the Hazard Analysis and Critical Control Point (HACCP) System
$15