AWWA WQTC58857 PDF

AWWA WQTC58857 PDF

Name:
AWWA WQTC58857 PDF

Published Date:
11/02/2003

Status:
Active

Description:

Analysis of Polar Turfgrass Pesticides in Water by ESI/LC/MS Coupled with SPE Technology

Publisher:
American Water Works Association

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$7.2
Need Help?
This study developed an electrospray ionization (ESI) liquid chromatography/mass spectrometry (LC/MS) method for the analysis of polar turfgrass pesticides that are commonly used in North America. The water samples were first extracted by using a solid phase extraction (SPE) technique. The analysis was then carried out with a Waters 2690 LC equipped with a ZMD detector. The separation was performed on a reverse phase C18 column. Acetonitrile/5 mM ammonium acetate in water were used as the solvents for the gradient mobile phase profile. The flowrate was set to 0.25 mL/min. The injection volume was 20 uL. This method was effectively used for the analysis of a number of turfgrass pesticides of low volatility in finished drinking water, groundwater, and surface water. These contaminants included bensulide, clopyralid, halofenozide, imidacloprid, mecoprop, neburon, oryzalin, paclobutrazol, triadimefon, triadimenol, etc. Bisphenol A-d16 was used as the internal standard. 4-(4'-bromophenyl)phenol was used as the surrogate. The calibrations were in a range of 0.05-30 ug/L. The method detection limits (MDLs) were determined by measuring seven replicate laboratory fortified blanks spiked at the method reporting level (MRL) at 0.5 ug/L or less. The MDLs were calculated as a product of the standard deviation of the replicate analyses and the student's t value with a 99% confidence level and a n-1 degree of freedom. The method accuracy (mean recovery) and precision (relative standard deviation, RSD) were determined by measuring four replicate laboratory fortified blanks (LFBs) spiked at 5-10 ug/L. Includes 9 references, tables.
Edition : Vol. - No.
File Size : 1 file , 290 KB
Note : This product is unavailable in Ukraine, Russia, Belarus
Number of Pages : 3
Published : 11/02/2003

History


Related products

AWWA WQTC58853
Published Date: 11/02/2003
NDMA Analytical Methods Comparisons and its Occurrence in Missouri
$7.2
AWWA WQTC58892
Published Date: 11/02/2003
Retrofitting Large Water Utilities with Low-Pressure Membranes: Investigating Treatment, Construction, and Cost
$7.2
AWWA WQTC58893
Published Date: 11/02/2003
Comparison of Pretreatment Options for MF/UF Membrane Filtration
$7.2
AWWA WQTC58927
Published Date: 11/02/2003
Pilot- and Full-Scale Evaluation of Low-Pressure Membrane Processes for the Removal of Bacteria and Viruses
$7.2

Best-Selling Products

IEEE/ISO 10857-1994
Published Date: 04/27/1994
ISO/IEC/IEEE International Standard - Information Technology -- Microprocessor Systems -- Futurebus+(R) - Logical Protocol specification
$80.7
IEEE/ISO 11073-10101:2004/Amd 1:2017
Published Date: 10/01/2017
Health informatics -- Point-of-care medical device communication -- Part 10101: Nomenclature/Amd 1:2017
IEEE/ISO 11073-10101-2004/Amd 1-2017
Published Date: 03/26/2018
ISO/IEEE International Standard - Health informatics -- Point-of-care medical device communication -- Part 10101: Nomenclature AMENDMENT 1: Additional definitions
$47.7
IEEE/ISO 11073-10101-2004
Published Date: 12/15/2004
ISO/IEEE Health informatics -- Point-of-care medical device communication -- Part 10101: Nomenclature
$129.3
IEEE/ISO 11073-10101-2020
Published Date: 08/28/2020
ISO/IEEE International Standard - Health informatics-Device interoperability-Part 10101: Point-of-care medical device communication-Nomenclature
$108
IEEE/ISO 11073-10206-2024
Published Date: 08/07/2024
ISO/IEEE International Standard--Health informatics--Device interoperability--Part 10206: Personal health device communication--Abstract content information model
$31.8