A Façade Retrofit Solution for Improved Energy-Performance & Occupant-Comfort PDF

A Façade Retrofit Solution for Improved Energy-Performance & Occupant-Comfort PDF

Name:
A Façade Retrofit Solution for Improved Energy-Performance & Occupant-Comfort PDF

Published Date:
2019

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?
A methodology for retrofitting of facades, via the addition of single- or double-glazings, has been developed in order to improve both the energy-performance of an existing building envelope and occupant comfort. This process of retrofitting is executed from the inside of the building, when the building is in use and with minimal disturbance to occupants. It also requires minimal intervention from the facilities team of the building, and does not involve de-commissioning of an office space during the retrofitting process. As such, this methodology of retrofitting is simpler and cheaper to execute when compared to the traditional method of re-installation of a new glazing from outside the building with/without- dismantling the existing glazing. The retrofitting solution has been launched at the pilot-scale for retrofitting office spaces, and estimates of the heat-ingress through the glazings demonstrate energy savings of the order of 50%. Pre- and post- retrofit evaluation of the occupant thermal comfort in an office space, as quantified using spatial distributions of the operative temperature, reveals a significant improvement in the thermal comfort of the space close to the facade. Depending on the time of the day, the drop in the operative temperature is found to range from 1.5 to 4 oC at workstation locations closest to the façade. Additionally, significant improvement in the acoustic comfort is also noted, and the peak noise levels, measured close to the façade (inside the building), are seen to drop from 60dB for the pre-retrofit scenario to 39dB for the post-retrofit scenario.
File Size : 1 file , 1.5 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 8
Product Code(s) : D-Bldgs19-063
Published : 2019
Units of Measure : Dual

History


Related products


Best-Selling Products

EUROCAE ED-100A
Published Date: 04/01/2005
INTEROPERABILITY REQUIREMENTS FOR ATS APPLICATIONS USING ARINC 622 DATA COMMUNICATIONS (FANS 1/A INTEROP STANDARD)
$56.7
EUROCAE ED-101
Published Date: 08/01/2000
MINIMUM OPERATIONAL PERFORMANCE SPECIFICATION FOR MODE S SPECIFIC SERVICE APPLICATIONS
EUROCAE ED-102A
Published Date: 12/01/2009
Minimum Operational Performance Standards for 1090 MHz Extended Squitter Automatic Dependent Surveillance – Broadcast (ADS-B) and Traffic Information Services – Broadcast (TIS-B)
EUROCAE ED-102A
Published Date: 01/01/2012
Minimum Operational Performance Standards for 1090 MHz Extended Squitter Automatic Dependent Surveillance – Broadcast (ADS-B) and Traffic Information Services – Broadcast (TIS-B)
EUROCAE ED-102B CHG 1
Published Date: 01/01/2022
MINIMUM OPERATIONAL PERFORMANCE STANDARDS (MOPS) FOR 1090 MHZ EXTENDED SQUITTER AUTOMATIC DEPENDENT SURVEILLANCE - BROADCAST (ADS-B) AND TRAFFIC INFORMATION SERVICES-BROADCAST (TIS-B) - CHANGE 1
$48.6
EUROCAE ED-102B
Published Date: 12/01/2020
MINIMUM OPERATIONAL PERFORMANCE STANDARDS (MOPS) FOR 1090 MHZ EXTENDED SQUITTER AUTOMATIC DEPENDENT SURVEILLANCE ‐ BROADCAST (ADS‐B) AND TRAFFIC INFORMATION SERVICES‐BROADCAST (TIS‐B)
$311.1