CI-01-05-1 -- Natural Convection Effects in Three-Dimensional Window Frames with Internal Cavities PDF

CI-01-05-1 -- Natural Convection Effects in Three-Dimensional Window Frames with Internal Cavities PDF

Name:
CI-01-05-1 -- Natural Convection Effects in Three-Dimensional Window Frames with Internal Cavities PDF

Published Date:
2001

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

This paper studies three-dimensional natural convection effects in window frames with internal cavities. Infrared (IR) thermography experiments, computational fluid dynamics (CFD) simulations, and calculations with traditional software for simulating two-dimensional heat conduction were conducted. The IR thermography experiments mapped surface temperatures during steady-state thermal tests between ambient thermal chambers set at 0ºC and 20ºC. Using a non-contact infrared scanning radiometer and an external referencing technique, we were able to obtain surface temperature maps with a resolution of 0.1ºC and 3 mm and an estimated uncertainty of ±0.5ºC and ±3 mm. The conjugate CFD simulations modeled the enclosed air cavities, frame section walls, and foam board surround panel. With the two-dimensional heat conduction simulation software, we used correlations to model heat transfer in the air cavities. For both the CFD simulations and the conduction simulation software, boundary conditions at the external air/solid interface were modeled using constant surface heat-transfer coefficients with fixed ambient air temperatures. Different cases were studied, including simple, four-sided frame sections (with one open internal cavity), simple vertical sections with a single internal cavity, and horizontal sections with a single internal cavity. The sections tested in the Infrared Thermography Laboratory (IR lab) were made of PVC. Both PVC and thermally broken aluminum sections were modeled. Based on the current investigations, it appears that the thermal transmittance or U-factor of a four-sided section can be found by calculating the average of the thermal transmittance of the respective single horizontal and vertical sections. In addition, we conclude that two-dimensional heat transfer simulation convection correlations used for the internal cavities are correct.

Units: SI


File Size : 1 file , 730 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 11
Product Code(s) : D-7057
Published : 2001

History


Related products


Best-Selling Products

CI/Chlor 89
Published Date: 01/01/2006
Chlorine Scrubbing Systems, Third Edition
$27