DA-88-22-1 -- Energy Requirements for Closed Loop Storage Heat Pump Systems with Different Internal Loads for Various Geographic Locations PDF

DA-88-22-1 -- Energy Requirements for Closed Loop Storage Heat Pump Systems with Different Internal Loads for Various Geographic Locations PDF

Name:
DA-88-22-1 -- Energy Requirements for Closed Loop Storage Heat Pump Systems with Different Internal Loads for Various Geographic Locations PDF

Published Date:
1988

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

The energy efficiency of closed-loop water storage heat pump systems is strongly dependent on the quantity of internal heat that is generated and stored for later usage. In addition, the relative severity of the heating and cooling seasons will also influence the energy efficiency of these types of systems. For this study, a commercially available building energy analysis computer program was used in order to make comparisons of energy requirements (supplementary heat, cooling tower, compressor, HVAC system, and total building) for a range of internal loads (W/ft 2) at various locations throughout the United States. The building used in the study was a 46,000 ft2, two-story office building. The energy requirements were evaluated on an hour-by-hour basis for a full year using ASHRAE TRY weather data for 17 major cities in the U.S. The building was divided into 16 zones with two water-to-air heat pumps per zone and a total water storage volume of 40,000 gallons. The results of the analysis for an internal loading range of 0.5 to 6 W/ft2 indicated that the supplementary energy, cooling tower energy and total building energy were strongly dependent on the internal load as well as the location of the building. The HVAC energy requirements however, exhibited a minimum energy requirement at a specific internal load. This minimum energy point correlated reasonably well with the number of degree days at the location.

Units: Dual (abstract I-P only)

 


File Size : 1 file , 2.1 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 12
Product Code(s) : D-DA-88-22-1
Published : 1988

History


Related products


Best-Selling Products

CABC CAAC
Published Date: 01/01/2010
California Administrative Code - California Code of Regulations Title 24, Part 1
$14.7
CABC CAAC
Published Date: 01/01/2016
California Administrative Code - California Code of Regulations Title 24, Part 1
$20.4
CABC CAAC
Published Date: 06/01/2007
California Administrative Code - California Code of Regulations Title 24, Part 1
$13.8
CABC CAAC
Published Date: 01/01/2019
California Administrative Code - California Code of Regulations Title 24, Part 1
$19.2
CABC CABC VOL 1
Published Date: 06/01/2007
California Building Code - California Code of Regulations Title 24, Part 2, Volume 1 of 2
$74.4
CABC CABC VOL 1
Published Date: 01/01/2019
California Building Code - California Code of Regulations Title 24, Part 2, Volume 1 of 2