NO-94-10-1 -- Evaluation of the Environmental Conditions in a Filter-Capped Cage Using a One-Way Airflow System PDF

NO-94-10-1 -- Evaluation of the Environmental Conditions in a Filter-Capped Cage Using a One-Way Airflow System PDF

Name:
NO-94-10-1 -- Evaluation of the Environmental Conditions in a Filter-Capped Cage Using a One-Way Airflow System PDF

Published Date:
1994

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Deterioration of intra-cage ventilation and rising temperatures are common problems when filter caps are used to prevent cross-infection. Hypothesised that the use of a one-way air flow system (OWAS) to control air flow in the rack could also control increasing temperatures. Hence, experiments comparing the use of a one-way air flow system to that of a conventional ventilation system (CVS) were performed. For each system, the intra-cage temperatures - with and without the filter cap - for a varying number (zero, one, two, and three) of young adult rats were measured and found the greater temperature increases to be in the cage with the filter caps. Furthermore, temperature deviations were found to be related to the number of animals in a cage and the interface temperature gradient to be lessened when an OWAS for a filter-capped cage was used. This suggested improvement of the ventilation inside the cages.

KEYWORDS: calculating, microclimate, deteriorating, ventilation, temperature, filters, caps, air flow, experiment, comparing, measuring, temperature difference, laboratory animal housing, animal housing, once through air conditioning.


File Size : 1 file , 610 KB
Note : This product is unavailable in Russia, Belarus
Product Code(s) : D-17836
Published : 1994

History


Related products


Best-Selling Products

PDA PTC PUPSIT 1
Published Date: 02/01/2020
Points to Consider for Risks Associated with Sterilizing Grade Filters and Sterilizing Filtration
$97.5
PDA PTC PUPSIT 2
Published Date: 03/01/2020
Points to Consider for Implementation of Pre-Use Post-Sterilization Integrity Testing (PUPSIT)
$97.5
PDA TR 13-2
Published Date: 11/01/2020
Technical Report No. 13-2 Fundamentals of an Environmental Monitoring Program Annex 1: Environmental Monitoring of Facilities Manufacturing Low Bioburden Products
$97.5
PDA TR 13
Published Date: 06/01/2014
Technical Report 13 Revised, (TR 13) Fundamentals of an Environmental Monitoring Program
$97.5
PDA TR 13
Published Date: 04/22/2022
Technical Report 13 Revised 2022, (TR 13) Fundamentals of an Environmental Monitoring Program
$97.5
PDA TR 14
Published Date: 09/01/2008
PDA Technical Report No. 14 (TR 14) Validation of Column-Based Chromatography Processes for the Purification of Proteins
$97.5