NY-08-010 -- Experimental Seismic-Performance Evaluation of Integrated Isolation/Restraint Systems for Heavy HVAC Equipment PDF

NY-08-010 -- Experimental Seismic-Performance Evaluation of Integrated Isolation/Restraint Systems for Heavy HVAC Equipment PDF

Name:
NY-08-010 -- Experimental Seismic-Performance Evaluation of Integrated Isolation/Restraint Systems for Heavy HVAC Equipment PDF

Published Date:
2008

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Czech version):
200 business days

SKU:
ny-08-010-experimental-seismic-performance-evaluation-of-integrated-isolation-restraint-systems-for-heavy-hvac-equipment_1714298

Choose Document Language:
4.80 €
Need Help?

The experimental study presented in this paper is aimed at evaluating the seismic performance of integrated isolation/ restraint (I/R) systems for heavy HVAC equipment. Earthquake simulator experiments were conducted on a heavy centrifugal chiller supported by four I/R systems. The peak response quantities of the equipment and the peak dynamic forces induced into the I/R systems were considered as the key components for the seismic-performance evaluation of the I/R systems. The test plan included seismic and system-identification tests and incorporated different input motion amplitudes and different configurations of the restraint components of the I/R systems. The test results showed that limiting the displacement of the equipment by the impacts occurring in the restraint components of the I/R systems resulted in amplification of the acceleration response of the equipment and excessive dynamic forces induced into the I/R systems. Throughout the experiments, the I/R systems experienced dynamic forces much higher than their static design capacity. The configuration variables of the restraint component, particularly the gap size, were proven influential on the seismic performance of the I/R systems. Among different configurations of the restraint component considered in this study, the configuration with the smallest gap size resulted in the best overall seismic performance.

Units: Dual

 


File Size : 1 file , 5.6 MB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 12
Product Code(s) : D-NY-08-010
Published : 2008

History


Related products


Best-Selling Products

LIA Z136.1-2007
Published Date: 03/16/2007
Safe Use of Lasers
LIA Z136.1-2014
Published Date: 2013
Safe Use of Lasers
60.90 €
LIA Z136.1-2022
Published Date: 2022
Safe Use of Lasers
67.50 €
LIA Z136.2-2012
Published Date: 12/19/2012
Safe Use of Optical Fiber Communication Systems Utilizing Laser Diode and LED Sources
45.00 €
LIA Z136.3-2005
Published Date: 01/06/2005
Safe Use of Lasers in Health Care Facilities
LIA Z136.3-2011
Published Date: 12/05/2011
Safe Use of Lasers in Health Care Facilities
47.40 €