NR NR/L2/SIGELP/50000 ISSUE 3 PDF

NR NR/L2/SIGELP/50000 ISSUE 3 PDF

Name:
NR NR/L2/SIGELP/50000 ISSUE 3 PDF

Published Date:
03/04/2017

Status:
[ Revised ]

Description:

Safe Working and Maintenance on or near Signalling Power Distribution Equipment above 175 V

Publisher:
Network Rail

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$18.6
Need Help?
PDF ONLY

This standard defines the requirements for safe working practices, inspection and maintenance regimes, routine testing, defect and fault management of the following signalling power distribution equipment on Network Rail managed Infrastructure:

  • Signalling power distribution equipment above 175 V in equipment housings including FSPs, location cases, relay rooms, REBs, power pillars, etc.

  • Signalling Power distribution supply cabling

  • Insulation Monitoring equipment on signal power supplies above 175 V

  • Interrupter cabling

  • Temporary protective measures

  • Electronic Protection Relays installed on signalling power supplies above 175 V

  • Distribution Interface Transformer Assembly (DITA) equipment

  • 650V portable generation equipment.

The safety requirements apply to any individual involved in working on or near signalling power distribution equipment above 175 V.

The maintenance of Principal Supply Points is excluded from this document.

Purpose

This standard describes the minimum requirements for working on or near signalling power distribution equipment above 175 V on Network Rail managed Infrastructure, which includes:

  • Safe working practices. 

  • Maintenance and testing requirements.

  • Active fault and defect management.

This standard describes the means of compliance with the requirements of the Electricity at Work Regulations 1989 when working on or near signalling power supplies.

This has been written in accordance with HSE publication HSG85 – Electricity at Work Safe Working Practices (3rd Edition).


Edition : 3
File Size : 1 file , 1000 KB
Number of Pages : 30
Published : 03/04/2017

History

NR NR/L2/SIGELP/50000 ISSUE 5
Published Date: 12/02/2023
Safe Working and Maintenance on or near Signalling Power Distribution Equipment above 175 V AC
$18.6
NR NR/L2/SIGELP/50000 ISSUE 4
Published Date: 09/04/2021
Safe Working and Maintenance on or near Signalling Power Distribution Equipment Above 175 V AC
$18.6
NR NR/L2/SIGELP/50000 ISSUE 3
Published Date: 03/04/2017
Safe Working and Maintenance on or near Signalling Power Distribution Equipment above 175 V
$18.6
NR NR/L2/SIGELP/50000 ISSUE 2
Published Date: 12/03/2016
Specification for Safe Working and Maintenance on or near Signalling Power Distribution Equipment above 175 Volts
$18.6
NR NR/L2/SIGELP/50000 ISSUE 1
Published Date: 06/06/2015
Working on or Near 650V Signalling Power Supplies
$13.2

Related products

NR TEF 3242 ISSUE 1
Published Date: 06/01/2012
Level Crossing Vertical Profile Inspection Sheet (Lxi29)
$5.7
NR T25320 ISSUE 6
Published Date: 03/01/2014
Lineside and On-Track Typical Circuits - POINTS - Point Machine Drive Circuit
$5.7
NR NR/L2/CIV/005/01 ISSUE 1
Published Date: 06/02/2018
Drainage Systems Manual: Drainage Asset Management
$13.2
NR NR/CIV/SD/605 ISSUE C
Published Date: 12/01/2018
Collision Protection Beam: Steelwork Details
$5.7

Best-Selling Products

SPC GB 10409-2019
Published Date: 05/01/2020
Burglary-resistant safes (TEXT OF DOCUMENT IS IN CHINESE)
$81
SPC GB 14924.3-2010
Published Date: 12/23/2010
Laboratory Animals -- Nutrients For Formula Feeds
$42
SPC GB 14925-2010
Published Date: 12/23/2010
Laboratory Animal -- Requirements Of Environment And Housing Facilities
$72
SPC GB 175-2007
Published Date: 11/09/2007
Common Portland Cement
$48
SPC GB 17820-2018e
Published Date: 06/01/2019
Natural Gas (TEXT OF DOCUMENT IS IN ENGLISH)
$150
SPC GB 17907-2010
Published Date: 01/10/2011
Mechanical Parking Systems -- General Safety Requirement
$72