LO-09-049 -- Comfort, Energy Consumption, and Economics of a School with Energy Recovery PDF

LO-09-049 -- Comfort, Energy Consumption, and Economics of a School with Energy Recovery PDF

Name:
LO-09-049 -- Comfort, Energy Consumption, and Economics of a School with Energy Recovery PDF

Published Date:
2009

Status:
Active

Description:

Publisher:
ASHRAE

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$4.8
Need Help?

Energy wheels are often used to reduce energy consumption and HVAC equipment capacities in buildings, but the effect of the energy wheel on the indoor comfort conditions has not been studied in detail. The addition of an energy wheel to the HVAC system may improve the indoor air relative humidity and perceived air quality as well as reduce energy consumption. A school building is modeled with the TRNSYS computer program, in four North American cities (Saskatoon, Saskatchewan; Vancouver, British Columbia; Tampa, Florida and Phoenix, Arizona) to see the effect of the energy wheel on the indoor comfort in different outdoor climates. The simulations are performed with an energy wheel and without an energy wheel to determine the effects of the energy wheel on the indoor RH and PAQ. Similar simulations have been performed on an office building and presented in a previous paper. The results from the school will be compared to the office building results. In the school, the energy wheel significantly reduces peak RH levels in Tampa. In Phoenix and Saskatoon there is a small reduction during some hours of the year and a slight increase during some hours of the year. This is due to their dry climates and the need to increase RH if it is too low. The addition of the energy wheel reduces the number of people that are dissatisfied with PAQ within the space in Tampa. In Saskatoon and Phoenix there is less of an effect on the percent dissatisfied with the PAQ. By using an energy wheel, the total energy consumed by the HVAC system is reduced in Saskatoon, Phoenix and Tampa. There is a significant reduction in the size of the heating equipment in Saskatoon and in the size of the cooling equipment in Phoenix, Tampa and Saskatoon. A cost analysis shows that the HVAC system including an energy wheel has the least life cycle costs in Saskatoon and Tampa. In Phoenix the life cycle cost is nearly the same for the energy wheel and the case without the energy wheel. In Vancouver, the energy wheel has a nefligible impact on the indoor RH, PAQ, energy consumption and life cycle cost.

 

Units: Dual 


File Size : 1 file , 980 KB
Note : This product is unavailable in Russia, Belarus
Number of Pages : 12
Product Code(s) : D-LO-09-049
Published : 2009

History


Related products


Best-Selling Products

DIN ISO/TS 10004
Published Date: 11/01/2011
Quality management - Customer satisfaction - Guidelines for monitoring and measuring (ISO/TS 10004:2010); Text in German, English and French
$45.78
DIN ISO/TS 10832
Published Date: 06/01/2011
Soil quality - Effects of pollutants on mycorrhizal fungi - Spore germination test (ISO/TS 10832:2009, corrected version 2010-01-15)
$23.217
DIN ISO/TS 11133-1
Published Date: 06/01/2009
Microbiology of food and animal feeding stuffs - Guidelines on preparation and production of culture media - Part 1: General guidelines on quality assurance for the preparation of culture media in the laboratory (ISO/TS 11133-1:2009); German version CEN ISO/TS 11133-1:2009
$29.103
DIN ISO/TS 11133-2
Published Date: 10/01/2004
Microbiology of food and animal feeding stuffs - Guidelines on preparation and production of culture media - Part 2: Practical guidelines on performance testing of culture media (ISO/TS 11133-2:2003); German version CEN ISO/TS 11133-2:2003
$31.392
DIN ISO/TS 11135-2
Published Date: 11/01/2008
Sterilization of health care products - Ethylene oxide - Part 2: Guidance on the application of ISO 11135-1 (ISO/TS 11135-2:2008); German version CEN ISO/TS 11135-2:2008
$40.875
DIN ISO/TS 11135-2
Published Date: 01/01/2010
Sterilization of health care products - Ethylene oxide - Part 2: Guidance on the application of ISO 11135-1 (ISO/TS 11135-2:2008); German version CEN ISO/TS 11135-2:2008, Corrigendum to DIN ISO/TS 11135-2:2008-11; German version CEN ISO/TS 11135-2:2008/AC:2009
$40.875