DANSK DS/CEN/TS 16817-1 PDF

DANSK DS/CEN/TS 16817-1 PDF

Name:
DANSK DS/CEN/TS 16817-1 PDF

Published Date:
10/28/2015

Status:
[ Active ]

Description:

Ambient air - Monitoring the effects of genetically modified organisms (GMO) - Pollen monitoring - Part 1: Technical pollen sampling using pollen mass filter (PMF) and Sigma-2-sampler

Publisher:
Dansk Standard

Document status:
Active

Format:
Electronic (PDF)

Delivery time:
10 minutes

Delivery time (for Russian version):
200 business days

SKU:

Choose Document Language:
$30.3
Need Help?

This Technical Specification describes a procedure for the use of the passive samplers Sigma-2 and PMF to sample airborne pollen. Both are designed to sample coarse aerosol particles. Collected samples are used to analyze pollen input with regard to pollen type and amount, and input of transgenic pollen. The Sigma-2 passive sampler here provides a standardized sampling method for direct microscopic pollen analysis and quantifying the aerial pollen input at the site. The PMF yields sufficient amounts of pollen to additionally carry out molecular-biological diagnostics for detection of GMO. Essential background information on performing GMO monitoring is given in Guideline VDI 4330 Part 1 [4], which is based on an integrated assessment of temporal and spatial variation of GMO cultivation (sources of GMO), the exposure in the environment and biological/ecological effects. Ideally, the pollen sampling using technical samplers for GMO monitoring should be undertaken in combination with the biological collection of pollen by bees (FprCEN/TS 16817-2). The application of technical passive samplers and the use of honey bee colonies as active biological collectors complement each other in a manifold way when monitoring the exposure to GMO pollen. Technical samplers provide results regarding the pollen input at the sampling site in a representative way, whereas with biological sampling by honey bee colonies, pollen from flowering plants in the area is collected according to the bees' collection activity. Thus, this method represents GMO exposure to roaming insects. By combining the two sampling methods these two main principles of exposure are represented. Furthermore, a broad range of pollen species is covered. The sample design depends on the intended measuring objective. Some examples are given in 6.2.


Edition : 15
File Size : 1 file , 2.3 MB
Number of Pages : 57
Product Code(s) : DS-051, DS-051
Published : 10/28/2015

History


Related products

DANSK DSF/ISO/IEC FDIS 5218
Published Date:
Information technology – Codes for the representation of human sexes
$13.5
DANSK DS/EN IEC 60335-2-51
Published Date: 12/07/2023
Household and similar electrical appliances – Safety – Part 2-51: Particular requirements for stationary circulation pumps for heating and service water installations
$15.3
DANSK DS/EN ISO 19345-2
Published Date: 06/18/2019
Petroleum and natural gas industry – Pipeline transportation systems -Pipeline integrity management specification – Part 2: Full-life cycle integrity management for offshore pipeline (ISO 19345-2:2019)
$38.7
DANSK DS/ISO 17089-1
Published Date: 08/26/2019
Measurement of fluid flow in closed conduits – Ultrasonic meters for gas – Part 1: Meters for custody transfer and allocation measurement
$47.4

Best-Selling Products

SN-CEN ISO/ASTM/TS 52930:2021
Published Date: 12/16/2021
Additive Manufacturing - Qualification principles - Installation, operation and performance (IQ/OQ/PQ) of PBF-LB equipment (ISO/ASTM/TS 52930:2021)